Ankleshwar
08048047734
+919426065609

laboratory instruments

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

Bottle Top Dispenser For Hydrofluoric ACID And High Purity Acids • Fully autoclavable at 121°C, 15 psi for 10-15 mins. • Smooth & soft plunger for ease of working. • Highly robust and reliable dispensing technique. • It has re-circulation valve for re-directing the liquid into the bottle for bubble free dispensing without any loss of reagent. • Adjustable delivery nozzle to facilitate dispensing ease in all demanding laboratory conditions. 180° Rotation for easy & effortless volume setting. • Specially designed adapter allows 360° rotation, providing full flexibility in working. • Specially designed, springless, PTFE valve manifold ensures high chemical compatibility and jamming free valve functioning. • PTFE Piston with ETP O-Ring ensures very high chemical compatibility & wiper like smooth, effortless piston movement. • Adaptors to fit most of the laboratory reagent bottles are provided in the following sizes : 28,30,32,36,40 & 45 mm. • Calibration as per ISO 8655 standards. Vol. Range(ml) : 0.25 – 2.5, 0.5 – 5.0, 1.0 – 10.0, 2.5 – 25.0, 5.0 – 50.0, 10.0 – 100.0

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

The CL54+ Deluxe (often listed as CL 54+) is an eco-friendly benchtop pH and ORP/Redox meter manufactured by Toshcon | Toshniwal for laboratory and industrial use. It is designed with a high input impedance amplifier to deliver quick response times and high accuracy. Key Features • Measurement Ranges: 0 to 14.00 pH and ± 1999 mV (for Redox/ORP measurements). • Accuracy & Resolution: ± 0.01 pH (± 1 digit) and 0.01 pH resolution. • Display: 3.5 digit 0.5-inch bright RED LED for clear visibility. • Amplifier: Features stable high input impedance of 10¹² Ohms. • Design & Build: Corrosion-free, ultra-lightweight ABS plastic housing. • Safety & Diagnostics: Includes an illuminated rocker ON-OFF switch and a unique self-check mode to verify if the meter is functioning properly without needing an electrode. • Temperature Compensation: Manual adjustment from 0 to 100°C. Standard Accessories Each unit typically comes complete with a pH Electrode, an electrode stand, buffer capsules (pH 4 and pH 7), and a dust cover. Optional Redox electrodes can also be used for ORP measurements.

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

After-Sales Service & Support At Alpha Chem, we are committed to providing prompt and reliable after-sales service and repair support to our valued customers across India. Our experienced service team ensures that your laboratory equipment operates efficiently with minimum downtime. Warranty All Alpha Chem laboratory equipment is covered by a 12-month warranty on parts and a 3-month warranty on labor from the date of installation. Travel expenses are not included under the warranty. During the warranty period, Alpha Chem will repair or replace any defective parts caused by manufacturing defects. The warranty becomes void if the equipment has been modified, tampered with, or repaired by unauthorized personnel. The warranty does not cover: - Damage during transportation - Routine maintenance and consumables - Damage caused by improper operation or misuse - Damage due to accidents, natural disasters, or other force majeure events Repair Services Alpha Chem provides repair and maintenance services for all laboratory equipment manufactured and supplied by us. Our service team handles repairs for temperature controllers, sensors, electronic circuits, timers, pressure controllers, and other critical components. If major repairs are required, we will provide a detailed quotation within 3 working days after inspecting the equipment. If the repair cost is not economically viable, we will recommend a replacement or exchange solution. We also undertake equipment modifications and upgrades based on customer requirements. Breakdown Service Calls Most service requests are initially resolved through telephone support by our technical engineers. If on-site service is required, our service department will register your complaint and schedule a visit by a qualified service engineer. - Ankleshwar, Panoli, Dahej, Jhagadiya & Saykha : Service response within 48 hours. - Other locations across India: Service response typically within 2–4 working days, depending on the distance from our service center. Annual Maintenance Contract (AMC) An Annual Maintenance Contract (AMC) is the most effective way to ensure the long-term performance, accuracy, and reliability of your laboratory equipment. Alpha Chem offers comprehensive AMC plans that include preventive maintenance, inspection, calibration support, priority breakdown service, and reduced equipment downtime. For more information about our AMC programs, please contact our sales and service team. Alpha Chem Email: alphachem.ank@gmail.com Contact us: 9558865609

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

Features : • User friendly • Micro processor based PID controller. • Temperature sensor PT100. • Magnetic drive pump for water circulation. • Inlet & Outlet provision. • CFC free PUF Insulation. • 180 Sec. compressor ‘ON’ delay timer to safe guard the compressor. • Data storage facility. (O) • High speed Ethernet communication. (O) • Password protected keypad lock. • Delta colour touch screen HMI with Ethernet connectivity. (O) • Safety cut off for high Low temperature. • Low water level alarm. • Stand by temperature. • Documents DQ,IQ,OQ ,PQ, Operating & Maintenance Manual Technical Specification • Temperature Range : -30 °C to 150 °C • Accuracy : 0.2°C • Pump flow rate:- 15 L/M • Temperature Resolution 0.1 • Accuracy : +/- 0.5 °C • Uniformity :+/- 2.0 °C Interface • Printer interface • PC interface Connectivity • RS 232, 484 and Ethernet Construction STD Model(S) • Inner chamber stainless steel 304, Outer • chamber CRCA Mild steel Powder coated Control system • Dual control system • Microprocessor PID controller • PLC controller with LCD display 4.3” or 7” colour touch screen Contact us : 9558865609 Mail us : alphachem.ank@gmail.com

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

Alpha Chem Manufacture and Exporter of Round & Rectangular Vacuum Ovens GMP Model. Vacuum ovens are commonly using the temp range from 50 ºC to 200 ºC. Double wall construction, inner chamber is made out of stainless steel 304 & outer of stainless steel 304, glass wool insulation is provided all around the chamber to minimize heat loss due to radiation. The door is provided with a toughened glass window to view the samples placed inside. The digital temp is controlled & indicated by a Maximum vacuum: 760 mm of Hg. Mains 220 230 V.AC

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

Hanna’s HI98107 pHep® pH tester displays readings with 0.1 pH resolution, ±0.1 pH accuracy, and a range from 0.0 to 14.0 pH. This rugged, reliable, ergonomic, pocket-sized tester is designed for use in the lab or fields while keeping things simple with a two-button operation. > Extractable Cloth Junction to Extend pH Electrode Life > Has Automatic Temperature Compensation > For Use in Fresh Water

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

ALPHA CHEM is One Of The Leading Manufacturer and Supplier of Orbital Shaker Incubator, Laboratory Incubators, Laboratory Oven, Testing Equipments, Water Bath, Laboratory Chamber & Muffle Furnace. Industrial muffle furnaces are specially designed to suit IS & ASTM Standard. IT is applied in growing fields of Chemical industries, Pharma Unit, Medical research, Agricultural industrial, metal treatment, ash determination & wool industries. Technical Specification: • Outside Body made of M.S. Sheet powder coated • Inner muffle of Ceramic with high grade ceramic instillation • Door insulation of HFK bricks • This is surrounded by ceramic fibre blankets on all the four sides and reduce heat losses to a minimum. • Heating element are made from kanthal A1 Wire • A Uniform distribution through all 4 sides with mental wire • Max. Working temp up to 1000˚C & High temperature upto 1400 ˚C • Micro Processor PID Digital temp. Controller cum indicator fitted on top side of the unit with indicating lamps & switches • A special type of thermocouple fuse for safety to avoid over heating • Power supply 230 Volts, 50 H2 • Sizes available for industrial muffle furnaces are as below.

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

ALPHA CHEM is One Of The Leading Manufacturer and Supplier of Orbital Shaker Incubator, Laboratory Incubators, Laboratory Oven, Testing Equipments, Water Bath, Laboratory Chamber & SOXHLET EXTRACTION UNIT. Ideal heater for the extractors of soxhlet and other type. This apparatus I suitable to heat soxhlet flasks of 50- 1000ml. it consists of M.S. Sheet housing two vertical & two horizontal rods with adopters and screws to hold the flasks. To work on 220/230 volts AC. Supply. Features • Includes accessories • With non-slip rubber feet • Durable construction for long-lasting use • Borosilicate flask, extractor & condenser • Independent heating control for each position • Available in single and multiple heating positions • Electronic circuit-based heat controller for uniform heating • User-friendly controls for simplified operation and maintenance

6814772a5d263414004dd4a4 Card 2

product image
Laboratory Instruments

ALPHA CHEM is One Of The Leading Manufacturer and Supplier of Orbital Shaker Incubator, Laboratory Incubators, Laboratory Oven, Testing Equipments, Water Bath, Laboratory muffle furnace & Stability Chamber. Application : Used for large number of sample in hospitals, Research institution. Public health laboratories etc. These chamber can be used for environment testing of production sample & large size equipments where temp. & humidity are to be controlled. They are suitable for storage of electronic components, biological specimen & accelerated ageing test of large number of pharmaceutical samples. They can also used for botany, cytological, Deptsrturents, plan & animal breeding laboratories where controlled condition of temp. humidity & illumination are required. Ecocentric System : Chamber runs on the basis of Dewpoint control. Less deviations during short-term door opening & power failure. Less utility area Increased storage area. Low operating cost. Minimum power & water consumption. Reduced deviations. Less breakdowns due to standby refrigeration & humidification system. Due to PLC HMI & controlling through microprocessor based PID Temp. & RH operations the on time of both Temp. & RH system is reduced & efficiency of this system is increased with reduced energy consumption Ecocentric System : These chamber are Double wall PUF insulated modular panel. Construction material shall be double walled construction with backside triple. Insulation shall be thick PUF Insulation Exterior executed in Stainless Steel SS 304. Interior executed in Stainless Steel SS 304. The door shall be made of 80 mm thick PUF insulated panel clad with SS 304 inner & SS 304 inner on outer, flash type fitted with glass viewing window, imported Cam hinges, lock, and door closer. The door is sealed with the silicon gasket to prevent the leakage. Shall have Full view observation Acrylic door with gasket to observe sample inside the chamber. Lockable & Movable PU wheels for easy movement. Trays : Removable SS bar type trays of suitable size are provided, are adjustable up to 0.5 inch increment/decrement and slide out for easy clean up Air Circulation : The Stability chamber is provided with best air circulation to give better temperature uniformity this is achieved by using one set of motor & blower in baffle wall Compartment to push treated air in working chamber. This system gives better than 1 deg c. temperature uniformity in working chamber, evaporator, heaters & steam injection system is from back side, behind baffle wall, the air circulation blower is also fitted in this compartment only. This arrangement helps to mix steam and air together and pass well mixed air inside the working chamber. Due to above system the temperature and humidity (R.H.) in complete chamber almost remains equal.

Subcategory Tags

Phone Number

08048047734

Please keep 0 before dialling the number.

Email Address alphachem.ank@gmail.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address 1st Floor, Plot no. 141-1/15, opp. Verni Gastech Pvt, near Fire Station, Ankleshwar GIDC, Ankleshwar, Gujarat 393002

Ankleshwar, India, 393002